Global configuration parameters for ArtNet, sACN and DMX .
The Usine's light engine can manage Enttec Open DMX, Enttec USB pro devices, as well as all ArtNet and sACN devices connected to the Ethernet port.
But on Mac OSX you'll probably have installation troubles with DMXUSB PRO devices. It's generally caused by FTDI drivers conflicts. So in this case you can try the utility app free FTDI Driver Control 1.0.3 to disable the built-in FTDI driver.
Rescans all connected USB DMX devices. Usine can connect up to four devices.
Resets all connected devices (shutdown and restart). Use it if you encounter issues.
List of Connected USB DMX devices to activate inside Usine.
Turns the DMX engine ON. Must be activated to run Usine's DMX.
Number of actives plots.
Turns the ArtNet engine ON.
Output port used for the ArtNet communication (send messages). By default the port is 6454.
Activates the reception of ArtNet messages in Usine. To get messages use the light-artnet-sacn-input.
Input port used for the ArtNet communication (get incoming messages). By default the port is 6454.
When ON Usine's, Usine will automatically send 'ArtNet Poll' data to retrieve all connected devices.
Sends an 'ArtNet Poll' data manually, useless if ArtNet automatic poll is ON.
List of all connected ArtNet devices.
Turns the sACN engine ON.
Output port used for the sACN communication (send messages). By default the port is 5568.
Activates the reception of sACN messages in Usine. To get messages use the light-artnet-sacn-input.
Input port used for the sACN communication (get incoming messages). By default the port is 5568.
Sets the maximum DMX frame rate (packets sent per second). Usine will send packets only if necessary.
Clears all DMX parameter set as "master" when the engine is turned OFF (Blackout).